Counter adopts vacuum packaging
Counting mechanism and measuring mechanism adopt magnetic transmission
It has the advantages of anti-condensation atomization and anti-magnetic function, which can overcome external magnetic field interference.
Counting mechanism can be 360 degrees Rotate
The technical parameters of this series of water meters comply with the international standard ISO4064.
Dry type (there are hot water meters, copper shell and iron shell for customers to choose)
The remote pulse output function can be added according to user requirements< /div>
Main technical parameters
Nominal diameter (mm) |
Measurement level (mm) |
Overload flow (qs) |
Common flow (qp) |
Boundary flow (qt) |
Minimum flow rate (qmin) |
Minimum reading |
Maximum reading |
m3/h |
L/h |
m3 |
15 |
A |
3 |
1.5 |
0.15 |
0.06 |
0.0001 |
9999 |
B |
Water temperature: cold water meter not higher than 40℃ (hot water meter not higher than 90℃) and not lower than 0℃
pressure: not higher than 1MPa
Terms of use
From the low zone including the minimum flow rate (qmin) to excluding the boundary flow rate (qt) ±5%
From including the boundary flow rate (qt) to the high zone including the overload flow rate (qs) ± 2%
Dimensions and weight
Model |
Caliber |
Length L |
Width B |
Height |
Connecting thread |
Weight (Kg) |
mm |
LXSG-15C |
15 |
165 |
85 |
104 |
G3/4B |
1.6 |